MASTERCLAVE®
Automated Culture Media Preparation System
- Improved workflow
- Batch to batch reproducibility
- Quality homemade culture media
További tájékoztatást szeretne?
MASTERCLAVE® is an automated culture media preparation system, and part of bioMérieux’ AES Blue Line. This range of solutions places automation at the heart of your laboratory and improves your workflow, from media to sample preparation.
Automated culture media preparation system : a quality solution
Available in three different capacities, the robust MASTERCLAVE® demonstrates high performance for the preparation of your culture media, agar or broth. With its high core temperature precision control, and its high efficiency stirring system, MASTERCLAVE® prepares your medium and guarantees :
-
Homogeneity
-
Fertility
-
Sterility
MASTERCLAVE®: workflow optimization through lab automation
Productivity: with MASTERCLAVE®, get rid of manual preparation steps such as stirring the media water and autoclaving bottles
- Reproducibility: with automation, avoid human error and benefit from batch to batch reproducibility
- Flexibility: MASTERCLAVE® is ideal for both agar and broth
- Ease-of-use: to start a cycle, simply add powder and distilled water into MASTERCLAVE®. No need to supervise your media during the cycle
2 different media preparation systems for your very own specific needs
- MASTERCLAVE 528: ideal for broth or agar and with a capacity of 5 to 28 litres, MASTERCLAVE 528 offers three different stirring speeds for distribution and can operate a complete cycle in 75 minutes
- MASTERCLAVE 60: with a capacity of 10 to 60 litres, this system guarantees standardized and cost-effective production, and can prepares 60 litres of media within 90 minutes
MASTERCLAVE® 528
Media preparation capacity 5 to 28 litres
Sterilization temperature: 95-125°C
Sterilization duration: 1 to 99 min
Distribution temperature: 25-80°C
Temperature compensation for high volume supplements addition. Accurate temperature control
Microprocessor-based regulation, accuracy +/- 0.5°C after temperature stabilization
Safety cover locks above 80°C
Power supply: 400V +/- 10% three-phase + neutral, 16A (or 230 V +/- 10%, 10 A three-phase w/o neutral, 20 A), 8 KW
W x H x D: 760 x 1100 x 580 mm /91 kg
30” x 43” x 23” / 200 lb
MASTERCLAVE® 60
Media preparation capacity 10 to 60 litres
Sterilization temperature : 95-125°C
Distribution temperature : 25-80°C
Temperature composition for high volume supplements addition
Accurate temperature control
Microprocessor-based regulation, accuracy +/- 0.5°C after temperature stabilization
Safety cover locks above 80°C, electronically controlled lid & safety cover closing
Built-in ticket printer (AESAT2000)
Power supply: 400V +/- 10% three-phase + neutral + ground, 32 A, 18 KW or 230 V +/- 10%, three-phase + ground, 32A
W x H x D: 1030 x 1250 x 700 mm / 170 kg
41” x 50” x 28” / 375 lb